Robbie wrote,

>
>We will be replacing some old network equipment with IP only routers. We
>currently are using Decnet IV for a lot of computer-computer
>communications. We have run some small tests in the lab using the Decnet
>over IP circuits without any problems. Most computers will have about 5
>or 6 decnet over IP circuits, but 2 computers will have 18 Decnet over IP
>circuits (going to 18 other VAX's.)
>
>My question: Is there any problem with 18 Decnet over IP circuits? Are
>there any parameter changes recommended?
>
>We are currently using MultiNet V4.3 Rev A-X, VAX 4000-105A, VAX/VMS
>V5.5-2H4, but will probably upgrade Multinet 5.0.
>
>Robbie Robertson
>Westinghouse Savannah River Co.
>(803) 725-1945
>Pager 17532
>



We have one VaxServer 3100 (very old) with 16mb of memory, running
VMS 5.4-3, with 25 DECnet over IP circuits with Multinet v4.4.

All I can find (it has been running fine for several years) are some
comments in MODPARAMS saying:

! 28-Mar-2002 Verne. MIN_NPAGEDYN from 671000 to 851000
! 26-Apr-2002 Verne. Min_IRP from 600 to 650.

and I assume I did that from watching actual usage of those items
on the running system (and assistance from AutoGen).


Verne
-----------------------------------------------------------------------
Verne Britton, Lead Systems Programmer voice: (304) 293-5192 x230
Systems Support Group (in WV, call 1-800-253-1558)
West Virginia Network for FAX: (304) 293-5540
Educational Telecomputing verne@wvnet.edu
837 Chestnut Ridge Road http://vaxa.wvnet.edu/~verne
Morgantown, WV 26505