Please Help - Tape Library - Veritas Backup Exec
This is a discussion on Please Help - Tape Library - Veritas Backup Exec ; I have just installed BENT V. 8.5 on a Compaq Proliant Server with NT Server
Service Pack 6. I installed the Library expansion Option because the library
has got two autoloaders. The problem is that backup exec is recognizing the
...
-
Please Help - Tape Library
I have just installed BENT V. 8.5 on a Compaq Proliant Server with NT Server
Service Pack 6. I installed the Library expansion Option because the library
has got two autoloaders. The problem is that backup exec is recognizing the
backup device as a stand-alone drive and not a library unit with two drives.
-
Re: Please Help - Tape Library
Dear John,
do the loaders show up as SCSI Devices in the System Control applet? Each Tape
Drive and each loader do have a different SCSI ID.
If so, I would assume that your specific autoloader is not supported by the
autoloader software.
Georg Schmitz
gs@kisters.de
John Babatunde wrote:
> I have just installed BENT V. 8.5 on a Compaq Proliant Server with NT Server
> Service Pack 6. I installed the Library expansion Option because the library
> has got two autoloaders. The problem is that backup exec is recognizing the
> backup device as a stand-alone drive and not a library unit with two drives.