An invalid command was provided (24682) - Veritas Backup Exec
This is a discussion on An invalid command was provided (24682) - Veritas Backup Exec ; Does anyone know what this means. I am testing BK 9.2 on a netware
6.5sp5 server with a Tandberg SLR140 with 8 tape autoloader.
BACKUPEXEC:list storage adapters
0x00 [V024-A0] Legacy FLOPPY Controller [slot 0]
0x01 [V024-A0-D1:0] Legacy Floppy
0x02 [V100-A100] ...
-
An invalid command was provided (24682)
Does anyone know what this means. I am testing BK 9.2 on a netware
6.5sp5 server with a Tandberg SLR140 with 8 tape autoloader.
BACKUPEXEC:list storage adapters
0x00 [V024-A0] Legacy FLOPPY Controller [slot 0]
0x01 [V024-A0-D1:0] Legacy Floppy
0x02 [V100-A100] USB UHCI Controller [slot 0]
0x03 [V025-A1] Novell ATA/IDE Host Adapter Module [slot 0]
0x07 [V025-A1-D1:0] Lite-On LTN483S 48x Max f/w:PD02
0x04 [V321-A2] Adaptec SCSI Card 29160 - Ultra160 SCSI [slot 2]
0x09 [V321-A2-D5:0] TANDBERGSLR140 0600
0x08 [V321-A2-D4:0] TANDBERGSLR AUTOLOADER 0303
0x05 [V321-A3] Adaptec AIC-7899 - Ultra160 SCSI [slot 10012]
0x0B [V321-A3-D1:0] SEAGATE ST336938LW f/w:0002
0x0A [V321-A3-D0:0] QUANTUM ATLAS 10K 18WLS f/w:UCHQ
0x06 [V321-A4] Adaptec AIC-7899 - Ultra160 SCSI [slot 10013]
Thanks,
Harvey Titanium
-
Re: An invalid command was provided (24682)
Harvey Titanium wrote:
> Does anyone know what this means. I am testing BK 9.2 on a netware
> 6.5sp5 server with a Tandberg SLR140 with 8 tape autoloader.
>
> BACKUPEXEC:list storage adapters
> 0x00 [V024-A0] Legacy FLOPPY Controller [slot 0]
> 0x01 [V024-A0-D1:0] Legacy Floppy
> 0x02 [V100-A100] USB UHCI Controller [slot 0]
> 0x03 [V025-A1] Novell ATA/IDE Host Adapter Module [slot 0]
> 0x07 [V025-A1-D1:0] Lite-On LTN483S 48x Max f/w:PD02
> 0x04 [V321-A2] Adaptec SCSI Card 29160 - Ultra160 SCSI [slot 2]
> 0x09 [V321-A2-D5:0] TANDBERGSLR140 0600
> 0x08 [V321-A2-D4:0] TANDBERGSLR AUTOLOADER 0303
> 0x05 [V321-A3] Adaptec AIC-7899 - Ultra160 SCSI [slot 10012]
> 0x0B [V321-A3-D1:0] SEAGATE ST336938LW f/w:0002
> 0x0A [V321-A3-D0:0] QUANTUM ATLAS 10K 18WLS f/w:UCHQ
> 0x06 [V321-A4] Adaptec AIC-7899 - Ultra160 SCSI [slot 10013]
That error usually points towards a hardware issue. However, you could
try the following:
1. BESTOP
2. Rename :\bkupexec\mm to mm.old
3. BESTART
Also, if you have anti-virus software running on this server, make sure
that the bkupexec folder is excluded from being scanned.
-
Re: An invalid command was provided (24682)
Chris wrote:
> Harvey Titanium wrote:
>
>> Does anyone know what this means. I am testing BK 9.2 on a netware
>> 6.5sp5 server with a Tandberg SLR140 with 8 tape autoloader.
>>
>> BACKUPEXEC:list storage adapters
>> 0x00 [V024-A0] Legacy FLOPPY Controller [slot 0]
>> 0x01 [V024-A0-D1:0] Legacy Floppy
>> 0x02 [V100-A100] USB UHCI Controller [slot 0]
>> 0x03 [V025-A1] Novell ATA/IDE Host Adapter Module [slot 0]
>> 0x07 [V025-A1-D1:0] Lite-On LTN483S 48x Max f/w:PD02
>> 0x04 [V321-A2] Adaptec SCSI Card 29160 - Ultra160 SCSI [slot 2]
>> 0x09 [V321-A2-D5:0] TANDBERGSLR140 0600
>> 0x08 [V321-A2-D4:0] TANDBERGSLR AUTOLOADER 0303
>> 0x05 [V321-A3] Adaptec AIC-7899 - Ultra160 SCSI [slot 10012]
>> 0x0B [V321-A3-D1:0] SEAGATE ST336938LW f/w:0002
>> 0x0A [V321-A3-D0:0] QUANTUM ATLAS 10K 18WLS f/w:UCHQ
>> 0x06 [V321-A4] Adaptec AIC-7899 - Ultra160 SCSI [slot 10013]
>
> That error usually points towards a hardware issue. However, you could
> try the following:
>
> 1. BESTOP
> 2. Rename :\bkupexec\mm to mm.old
> 3. BESTART
>
> Also, if you have anti-virus software running on this server, make sure
> that the bkupexec folder is excluded from being scanned.
>
That did the trick. Thanks
HT