NW6 abends and halts after full backup - Veritas Backup Exec

This is a discussion on NW6 abends and halts after full backup - Veritas Backup Exec ; NW6 sp2 abends and halts after full backup when eject tape or quick check. I use NWASPI because when i try to use becdm the Netware server hang up. The hardware is seagate scorpion 40 dds-4, adaptek 2110s RAID controller. ...

+ Reply to Thread
Results 1 to 5 of 5

Thread: NW6 abends and halts after full backup

  1. NW6 abends and halts after full backup



    NW6 sp2 abends and halts after full backup when eject tape or quick check.
    I use NWASPI because when i try to use becdm the Netware server hang up. The
    hardware is seagate scorpion 40 dds-4, adaptek 2110s RAID controller. Help
    me please.

    Server INDUS halted Tuesday, 5 August 2003 1:04:18.810
    Abend 1 on P00: Server-5.60c-0: NWPA-051: HAM could not find HACB on abort.

    Registers:
    CS = 0008 DS = 0010 ES = 0010 FS = 0010 GS = 0010 SS = 0010
    EAX = FFFFFFFE EBX = D0950600 ECX = D0950000 EDX = 00000000
    ESI = D2B48060 EDI = D2B46060 EBP = 00000000 ESP = D2B10E38
    EIP = D091A94A FLAGS = 00000097
    D091A94A C783F400000000 MOV [EBX+000000F4]=D2B10E3C,00000000
    000000
    EIP in NWPA.NLM at code start +0000794Ah

    The violation occurred while processing the following instruction:
    D091A94A C783F400000000 MOV [EBX+000000F4],00000000
    000000
    D091A954 83C404 ADD ESP,00000004
    D091A957 C683EF00000000 MOV [EBX+000000EF],00
    D091A95E BD0B000000 MOV EBP,0000000B
    D091A963 E969FEFFFF JMP D091A7D1
    D091A968 8B1424 MOV EDX,[ESP]
    D091A96B 85D2 TEST EDX,EDX
    D091A96D 7519 JNZ D091A988
    D091A96F C683EF00000000 MOV [EBX+000000EF],00
    D091A976 C783D800000003 MOV [EBX+000000D8],00000003
    000000



    Running process: Server 06 Process
    Thread Owned by NLM: SERVER.NLM
    Stack pointer: D2B10F80
    OS Stack limit: D2B09040
    CPU 0 (Thread D2B073A0) is in a NO SLEEP state
    Scheduling priority: 67371008
    Wait state: 50500F0 Waiting for work
    Stack: -D092A914 (NWPA.NLM|(Data Start)+914)
    --00000000 ?
    --00000046 ?
    D091A6F4 (NWPA.NLM|HAM_Abort_Routine+0)
    C6AF5700 (AD_ASPI.NLM|BE_GetSetVirtualMode+490)
    --00000000 ?
    --D0950600 ?
    D091F91D (NWPA.NLM|HACB_Abort_Routine+A9)
    --D0950600 ?
    --00000000 ?
    --C33C23C0 ?
    --D2B10ECC ?
    --0000000B ?
    D091AE7E (NWPA.NLM|HAM_Initial_Abort_Routine+2E)
    --D0950600 ?
    --00000000 ?
    --00000000 ?


    or



    Server INDUS halted Monday, 4 August 2003 1:28:32.844
    Abend 1 on P00: Server-5.60c: Page Fault Processor Exception (Error code
    00000002)

    Registers:
    CS = 0008 DS = 0010 ES = 0010 FS = 0010 GS = 0010 SS = 0010
    EAX = 35CDFA00 EBX = D0950A20 ECX = 35CDFA20 EDX = D0950A24
    ESI = 00000000 EDI = 0012D560 EBP = 00000001 ESP = BBCBEA40
    EIP = D2B39617 FLAGS = 00010002
    D2B39617 804E1C10 OR [ESI+1C]=?,10
    EIP in SCSIOSM.HAM at code start +00001617h
    Access Location: 0x0000001C

    The violation occurred while processing the following instruction:
    D2B39617 804E1C10 OR [ESI+1C],10
    D2B3961B 804B0780 OR [EBX+07],80
    D2B3961F 8B5358 MOV EDX,[EBX+58]
    D2B39622 52 PUSH EDX
    D2B39623 8B4350 MOV EAX,[EBX+50]
    D2B39626 8B8894000000 MOV ECX,[EAX+00000094]
    D2B3962C 51 PUSH ECX
    D2B3962D E8F2B6F5FD CALL IOPX.NLM|SgReleaseChainList
    D2B39632 83C408 ADD ESP,00000008
    D2B39635 53 PUSH EBX



    Running process: Interrupt service routine (nested count 2)
    Interrupted process: VxNDMP_cd2fb4c0 Process
    Thread Owned by NLM: NDMPD.NLM
    Stack pointer: BBCBEAC8
    OS Stack limit: BBCB7120
    Scheduling priority: 67371008
    Wait state: 5050100 Delayed
    Stack: --D2ACD060 ?
    --35CDFA20 ?
    D0A8A278 (IOPX.NLM|EmptySharedMemoryQueue+100)
    --00000000 ?
    --35CDFA20 ?
    --00000000 ?
    --BBCBEAC0 ?
    D369F549 (LSL.NLM|LSLPollProcedure+99)
    --CD4D63C0 ?
    -0012D560 (LOADER.EXE|interruptVectorPool





  2. Re: NW6 abends and halts after full backup

    alex
    > NW6 sp2 abends and halts after full backup when eject tape or quick check.
    > I use NWASPI because when i try to use becdm the Netware server hang up. The
    > hardware is seagate scorpion 40 dds-4, adaptek 2110s RAID controller. Help
    > me please.


    You're hanging your tape device off a RAID controller? Bad practice -
    should be a seperate SCSI HBA for tape devices (that'd also go some way
    to explaining the lockup with BECDM.CDM). I'd suggest you change that
    first.

    Michael
    --
    "If it jams, force it. If it breaks,
    you probably needed a new one anyway"

    * Please post replies via the newsgroup *

  3. Re: NW6 abends and halts after full backup



    "Michael" wrote in message
    news:3f2f6b1d@ROSASTDMZ05....
    > alex
    > > NW6 sp2 abends and halts after full backup when eject tape or quick

    check.
    > > I use NWASPI because when i try to use becdm the Netware server hang up.

    The
    > > hardware is seagate scorpion 40 dds-4, adaptek 2110s RAID controller.

    Help
    > > me please.

    >
    > You're hanging your tape device off a RAID controller? Bad practice -
    > should be a seperate SCSI HBA for tape devices (that'd also go some way
    > to explaining the lockup with BECDM.CDM). I'd suggest you change that
    > first.
    >


    Thanks for your reply. But i dont have possibility to add new controller.
    Have you any more ideas?



  4. Re: NW6 abends and halts after full backup

    alex
    > Thanks for your reply. But i dont have possibility to add new controller.
    > Have you any more ideas?


    Afraid not until that's been taken out of the equation - the ABENDs both
    point at hardware to me. If you ring Veritas, they'll also tell you to
    put another controller in since they don't support what you're doing.

    Michael
    --
    "If it jams, force it. If it breaks, you probably
    needed a new one anyway"

    * Please post replies via the newsgroup *

  5. Re: NW6 abends and halts after full backup


    Wait 'til 9.1 out and you can backup to disk volume.

    "alex" wrote in message news:3f2f786b@ROSASTDMZ05....
    >
    >
    > "Michael" wrote in message
    > news:3f2f6b1d@ROSASTDMZ05....
    > > alex
    > > > NW6 sp2 abends and halts after full backup when eject tape or quick

    > check.
    > > > I use NWASPI because when i try to use becdm the Netware server hang

    up.
    > The
    > > > hardware is seagate scorpion 40 dds-4, adaptek 2110s RAID controller.

    > Help
    > > > me please.

    > >
    > > You're hanging your tape device off a RAID controller? Bad practice -
    > > should be a seperate SCSI HBA for tape devices (that'd also go some way
    > > to explaining the lockup with BECDM.CDM). I'd suggest you change that
    > > first.
    > >

    >
    > Thanks for your reply. But i dont have possibility to add new controller.
    > Have you any more ideas?
    >
    >




+ Reply to Thread