attachments scrubbed from prior post.. inlined below


-------------- next part --------------
An embedded and charset-unspecified text was scrubbed...
Name: DELL-RAC-MIB.txt

DELL-RAC-MIB DEFINITIONS ::= BEGIN

IMPORTS
enterprises
FROM SNMPv2-SMI
OBJECT-TYPE
FROM SNMPv2-SMI
TRAP-TYPE
FROM RFC-1215;


-- text convention
------------------------------------------------------------------------


DisplayString ::= OCTET STRING


------------------------------------------------------------------------
-------
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
-- SIZE (0..1023)

------------------------------------------------------------------------
-------
DellString ::= DisplayString (SIZE (0..1023))

DellRacType ::= INTEGER
{
other(1), -- the DRAC type is not one of
the following
unknown(2), -- the DRAC type is unknown
DracIII(3), -- Drac III
ERA(4), -- ERA
DRAC4(5), -- Drac 4
DRAC5(6), -- Drac 5
DRAC5MC(7), -- Drac 5/MC
CMC(8), -- CMC
iDRAC(9) -- iDRAC
}

DellStatus ::= INTEGER
{
other(1), -- the status of the object is
not one of the following:
unknown(2), -- the status of the object is
unknown

-- (not known or monitored)
ok(3), -- the status of the object is
ok
nonCritical(4), -- the status of the object is
warning, non-critical
critical(5), -- the status of the object is
critical (failure)
nonRecoverable(6) -- the status of the object is
non-recoverable (dead)
}


------------------------------------------------------------------------
-------
-- DellPowerReading is a string representation of a floating
point value,
-- having exactly 3 digits of precision, and a maximum of 31
characters.
--
-- DellChassisPowerIndexRange defines the possible chassis power
instances
-- in this MIB.
--
-- DellCMCPSUIndexRange defines the possible CMC Power Supply
Unit (PSU)
-- instances, per chassis power instance, in this MIB.
--
-- DellCMCPSUCapable is an enumeration of PSU presence and/or
monitoring
-- capabilities.

------------------------------------------------------------------------
-------
DellPowerReading ::= DisplayString (SIZE (0..32))

DellCMCPowerIndexRange ::= INTEGER (1..1)

DellCMCPSUIndexRange ::= INTEGER (1..6)

DellCMCPSUCapable ::= INTEGER
{
absent(0), -- power supply is not present
none(1), -- no power monitoring abilities
basic(2) -- basic power monitoring abilities
}


------------------------------------------------------------------------
-------
-- DellTimestamp is defined in the displayable format:
--
-- yyyymmddHHMMSS.uuuuuuDooo
--
-- where yyyy is the year, mm is the month number, dd is the day
of the month,
-- HHMMSS are the hours, minutes and seconds, respectively,
uuuuuu is the
-- number of microseconds, D is the UTC offset direction, and
ooo is the
-- offset from UTC, in minutes.
--
-- Note: D is a plus (+) sign if east of UTC, and a minus (-) if
west of UTC.
--
-- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT
-- would be represented as: 19940525133015.000000-300

------------------------------------------------------------------------
-------
DellTimestamp ::= DisplayString (SIZE (26))


-- MIB Objects and Tables
--------------------------------------------------------

dell OBJECT IDENTIFIER ::= {
enterprises 674 }
server3 OBJECT IDENTIFIER ::= { dell
10892 }
drsOutofBandGroup OBJECT IDENTIFIER ::= { server3
2 }
drsInformationGroup OBJECT IDENTIFIER ::= {
drsOutofBandGroup 1 }
drsProductInfoGroup OBJECT IDENTIFIER ::= {
drsInformationGroup 1 }
drsFirmwareGroup OBJECT IDENTIFIER ::= {
drsInformationGroup 2 }

drsStatusGroup OBJECT IDENTIFIER ::= {
drsOutofBandGroup 2 }

drsChassisStatusGroup OBJECT IDENTIFIER ::= {
drsOutofBandGroup 3 }
drsStatusNowGroup OBJECT IDENTIFIER ::= {
drsChassisStatusGroup 1 }
drsStatusPrevGroup OBJECT IDENTIFIER ::= {
drsChassisStatusGroup 2 }
drsStatusChangeGroup OBJECT IDENTIFIER ::= {
drsChassisStatusGroup 3 }

drsChassisPowerGroup OBJECT IDENTIFIER ::= {
drsOutofBandGroup 4 }

DrsCMCPowerTableEntry ::= SEQUENCE
{
drsChassisIndex
DellCMCPowerIndexRange,
drsPotentialPower
DellPowerReading,
drsIdlePower
DellPowerReading,
drsMaxPowerSpecification
DellPowerReading,
drsPowerSurplus
DellPowerReading,
drsKWhCumulative
DellPowerReading,
drsKWhCumulativeTime
DellTimestamp,
drsWattsPeakUsage
DellPowerReading,
drsWattsPeakTime
DellTimestamp,
drsWattsMinUsage
DellPowerReading,
drsWattsMinTime
DellTimestamp,
drsWattsResetTime
DellTimestamp,
drsWattsReading
DellPowerReading,
drsAmpsReading
DellPowerReading
}

DrsCMCPSUTableEntry ::= SEQUENCE
{
drsPSUChassisIndex
DellCMCPowerIndexRange,
drsPSUIndex
DellCMCPSUIndexRange,
drsPSULocation
DellString,
drsPSUMonitoringCapable
DellCMCPSUCapable,
drsPSUVoltsReading
DellPowerReading,
drsPSUAmpsReading
DellPowerReading,
drsPSUWattsReading
DellPowerReading
}

drsCMCAlertGroup OBJECT IDENTIFIER ::= {
drsOutofBandGroup 20 }
drsChassisAlertVariables OBJECT IDENTIFIER ::= {
drsCMCAlertGroup 10 }
drsChassisAlertGroup OBJECT IDENTIFIER ::= {
drsCMCAlertGroup 2000 }

drsAlertGroup OBJECT IDENTIFIER ::= {
drsOutofBandGroup 5000 }
drsAlertVariables OBJECT IDENTIFIER ::= {
drsAlertGroup 10 }


-- Variables and Traps
------------------------------------------------------------------------


------------------------------------------------------------------------
-------
-- group: product information

------------------------------------------------------------------------
-------

drsProductName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0001 This attribute defines
the product name of a chassis management controller."
::= { drsProductInfoGroup 1 }

drsProductShortName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0002 This attribute defines
the short product name of a chassis management controller. "
::= { drsProductInfoGroup 2 }

drsProductDescription OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0003 This attribute defines
the product description of a chassis management controller. "
::= { drsProductInfoGroup 3 }

drsProductManufacturer OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0004 This attribute defines
the product manufacturer of a chassis management controller. "
::= { drsProductInfoGroup 4 }

drsProductVersion OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0005 This attribute defines
the product version of a chassis management controller. "
::= { drsProductInfoGroup 5 }

drsChassisServiceTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0007 This attribute defines
the Service Tag of the chassis. "
::= { drsProductInfoGroup 6 }

drsProductURL OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0006 This attribute defines
the out-of-band UI URL of a chassis management controller. "
::= { drsProductInfoGroup 7 }

drsProductChassisAssetTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0008 This attribute defines
the Asset Tag of the chassis. "
::= { drsProductInfoGroup 8 }

drsProductChassisLocation OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0009 This attribute defines
the location of the chassis. "
::= { drsProductInfoGroup 9 }

drsProductChassisName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0010 This attribute defines
the name of the chassis. "
::= { drsProductInfoGroup 10 }

drsSystemServiceTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0011 This attribute defines
the service tag of a system. "
::= { drsProductInfoGroup 11 }

drsProductSystemAssetTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0012 This attribute defines
the asset tag of a system. "
::= { drsProductInfoGroup 12 }

drsProductSystemSlot OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0013 This attribute defines
the slot number of a CMC. "
::= { drsProductInfoGroup 13 }

drsProductType OBJECT-TYPE
SYNTAX DellRacType
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0014 This attribute defines
type of a remote access card "
::= { drsProductInfoGroup 14 }

drsFirmwareVersion OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0002.0001 This attribute defines
the firmware version of a chassis management controller. "
::= { drsFirmwareGroup 1 }


------------------------------------------------------------------------
-------
-- group: chassis status

------------------------------------------------------------------------
-------

drsGlobalSystemStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0002.0001.0001 This attribute defines
the overall chassis status
being monitored by the chassis management card."
::= { drsStatusGroup 1 }

drsGlobalCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0001 This attribute defines
the overall chassis status
being monitored by the chassis management card."
::= { drsStatusNowGroup 1 }

drsIOMCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0002 This attribute defines
the IOM subsystem status
being monitored by the chassis management card."
::= { drsStatusNowGroup 2 }

drsKVMCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0003 This attribute defines
the iKVM subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 3 }

drsRedCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0004 This attribute defines
the Redundancy status
being monitored by the chassis management card."
::= { drsStatusNowGroup 4 }

drsPowerCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0005 This attribute defines
the power subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 5 }

drsFanCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0006 This attribute defines
the Fan subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 6 }

drsBladeCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0007 This attribute defines
the Blade subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 7 }

drsTempCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0008 This attribute defines
the Temp Sensor subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 8 }

drsCMCCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0009 This attribute defines
the CMC health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 9 }

drsGlobalPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0001 This attribute defines
the previous chassis status
recorded by the chassis management card."
::= { drsStatusPrevGroup 1 }

drsIOMPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0002 This attribute defines
the previous IOM subsystem status
recorded by the chassis management card."
::= { drsStatusPrevGroup 2 }

drsKVMPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0003 This attribute defines
the previous iKVM subsystem health status
recorded by the chassis management card."
::= { drsStatusPrevGroup 3 }

drsRedPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0004 This attribute defines
the previous Redundancy status
recorded by the chassis management card."
::= { drsStatusPrevGroup 4 }

drsPowerPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0005 This attribute defines
the previous power subsystem health status
recorded by the chassis management card."
::= { drsStatusPrevGroup 5 }

drsFanPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0006 This attribute defines
the previous Fan health status
being monitored by the chassis management card."
::= { drsStatusPrevGroup 6 }

drsBladePrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0007 This attribute defines
the previous Blade subsystem health status
recorded by the chassis management card."
::= { drsStatusPrevGroup 7 }

drsTempPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0008 This attribute defines
the Temp Sensor health status
being monitored by the chassis management card."
::= { drsStatusPrevGroup 8 }

drsCMCPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0009 This attribute defines
the CMC health status
being monitored by the chassis management card."
::= { drsStatusPrevGroup 9 }

drsGlobalChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0001 This attribute defines
the timestamp of the most recent
global status change."
::= { drsStatusChangeGroup 1 }

drsIOMChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0002 This attribute defines
the timestamp of the most recent
IOM status change."
::= { drsStatusChangeGroup 2 }

drsKVMChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0003 This attribute defines
the timestamp of the most recent
iKVM status change."
::= { drsStatusChangeGroup 3 }

drsRedChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0004 This attribute defines
the timestamp of the most recent
Redundancy status change."
::= { drsStatusChangeGroup 4 }

drsPowerChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0005 This attribute defines
the timestamp of the most recent
power health status change."
::= { drsStatusChangeGroup 5 }

drsFanChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0006 This attribute defines
the timestamp of the most recent
Fan health status change."
::= { drsStatusChangeGroup 6 }

drsBladeChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0007 This attribute defines
the timestamp of the most recent
Blade health status change."
::= { drsStatusChangeGroup 7 }

drsTempChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0008 This attribute defines
the timestamp of the most recent
Temp Sensor health status change."
::= { drsStatusChangeGroup 8 }

drsCMCChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0009 This attribute defines
the timestamp of the most recent
CMC health status change."
::= { drsStatusChangeGroup 9 }


------------------------------------------------------------------------
-------
-- group: chassis power

------------------------------------------------------------------------
-------

drsCMCPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF
DrsCMCPowerTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0001 This object defines
the CMC power table."
::= { drsChassisPowerGroup 1 }

drsCMCPowerTableEntry OBJECT-TYPE
SYNTAX DrsCMCPowerTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0001.0001 This object defines the
CMC power table entry."
INDEX { drsChassisIndex }
::= { drsCMCPowerTable 1 }

drsCMCPSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF DrsCMCPSUTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0002 This object defines
the CMC PSU table."
::= { drsChassisPowerGroup 2 }

drsCMCPSUTableEntry OBJECT-TYPE
SYNTAX DrsCMCPSUTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0002.0001 This object defines the
CMC PSU table entry."
INDEX { drsPSUChassisIndex, drsPSUIndex }
::= { drsCMCPSUTable 1 }


------------------------------------------------------------------------
-------
-- table: CMC power information

------------------------------------------------------------------------
-------

drsChassisIndex OBJECT-TYPE
SYNTAX DellCMCPowerIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0001 This
attribute defines the index
(one-based) of
the associated chassis."
::= { drsCMCPowerTableEntry 1 }

drsPotentialPower OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0002 This
attribute defines the power (in Watts) required by
the chassis
infrastructure, plus the sum of the maximum power requirements
for all
currently powered-on servers."
::= { drsCMCPowerTableEntry 2 }

drsIdlePower OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0003 This
attribute defines the power (in Watts) required by
the chassis
infrastructure, plus the sum of the minimum power requirements
for all
currently powered-on servers."
::= { drsCMCPowerTableEntry 3 }

drsMaxPowerSpecification OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0004 This
attribute defines the power limit (in Watts)
at which server
throttling will take place."
::= { drsCMCPowerTableEntry 4 }


drsPowerSurplus OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0005 This
attribute defines the power surplus (in Watts)
remaining above
the drsPotentialPower reading."
::= { drsCMCPowerTableEntry 5 }

drsKWhCumulative OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0006 This
attribute defines the cumulative chassis power
usage (in KWh)
since last reset."
::= { drsCMCPowerTableEntry 6 }

drsKWhCumulativeTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0007 This
attribute defines the timestamp of the most recent
chassis power
accumulator reset."
::= { drsCMCPowerTableEntry 7 }

drsWattsPeakUsage OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0008 This
attribute defines the chassis peak power
usage (in Watts)
since last reset."
::= { drsCMCPowerTableEntry 8 }

drsWattsPeakTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0009 This
attribute defines the timestamp of the most recent
chassis peak
power usage."
::= { drsCMCPowerTableEntry 9 }

drsWattsMinUsage OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0010 This
attribute defines the chassis mimimum power
usage (in Watts)
since last reset."
::= { drsCMCPowerTableEntry 10 }

drsWattsMinTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0011 This
attribute defines the timestamp of the most recent
chassis minimum
power usage."
::= { drsCMCPowerTableEntry 11 }

drsWattsResetTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0012 This
attribute defines the timestamp of the most recent
reset of the
chassis min/peak Watts readings."
::= { drsCMCPowerTableEntry 12 }

drsWattsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0013 This
attribute defines the instantaneous chassis power
usage (in
Watts)."
::= { drsCMCPowerTableEntry 13 }

drsAmpsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0014 This
attribute defines the instantaneous chassis current
usage (in
Watts)."
::= { drsCMCPowerTableEntry 14 }


------------------------------------------------------------------------
-------
-- table: CMC PSU info

------------------------------------------------------------------------
-------

drsPSUChassisIndex OBJECT-TYPE
SYNTAX DellCMCPowerIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0001 This
attribute defines the index
(one-based) of
the associated chassis."
::= { drsCMCPSUTableEntry 1 }

drsPSUIndex OBJECT-TYPE
SYNTAX DellCMCPSUIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0002 This
attribute defines the index
(one-based) of
the associated CMC PSU."
::= { drsCMCPSUTableEntry 2 }

drsPSULocation OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0003 This
attribute defines the location
of the CMC PSU."
::= { drsCMCPSUTableEntry 3 }

drsPSUMonitoringCapable OBJECT-TYPE
SYNTAX DellCMCPSUCapable
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0004 This
attribute defines the PSU Monitoring
capabilities, or
the absence of a PSU in this location."
::= { drsCMCPSUTableEntry 4 }

drsPSUVoltsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0005 This
attribute defines the instantaneous
PSU Voltage
reading."
::= { drsCMCPSUTableEntry 5 }

drsPSUAmpsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0006 This
attribute defines the instantaneous
PSU Current
reading."
::= { drsCMCPSUTableEntry 6 }

drsPSUWattsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0007 This
attribute defines the instantaneous
PSU Wattage
reading."
::= { drsCMCPSUTableEntry 7 }


------------------------------------------------------------------------
-------
-- group: chassis alerts

------------------------------------------------------------------------
-------

drsCASubSystem OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0001 This attribute defines
the Sub-System Name of the CMC Alert"
::= { drsChassisAlertVariables 1 }

drsCASSCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0002 This attribute defines
the Current Status of the Alerting
Sub-System"
::= { drsChassisAlertVariables 2 }

drsCASSPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0003 This attribute defines
the Previous Status of the Alerting
Sub-System"
::= { drsChassisAlertVariables 3 }

drsCASSChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0004 This attribute defines
the Timestamp of Most Recent Change of
the Alerting Sub-System"
::= { drsChassisAlertVariables 4 }

drsCAMessage OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0005 This attribute defines
the CSSD message of the CMC Alert"
::= { drsChassisAlertVariables 5 }

alertCMCTestTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
DESCRIPTION "The CMC has generated a test trap"
--#TYPE "CMC Test Trap"
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 2000

alertCMCNormalTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a return-to-normal or
informational event."
--#TYPE "CMC Return-to-Normal / Informational Trap"
--#SEVERITY NORMAL
--#CATEGORY Error Events
::= 2002

alertCMCWarningTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a warning event."
--#TYPE "CMC Warning Trap"
--#SEVERITY WARNING
--#CATEGORY Error Events
::= 2003

alertCMCCriticalTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a critical event."
--#TYPE "CMC Critical Trap"
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 2004

alertCMCNonRecoverableTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a catastrophic event."
--#TYPE "CMC Non-Recoverable Trap"
--#SEVERITY NON-RECOVERABLE
--#CATEGORY Error Events
::= 2005

--
-- Legacy Alerting
--

drsAlertSystem OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0001 Name of the system generating the alert."
--DEFAULT get-function-async get_%n_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 1 }

drsAlertTableIndexOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0002 0.0"
--DEFAULT get-function-async get_OID_null_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 2 }

drsAlertMessage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1024))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0003 Message describing the alert."
--DEFAULT get-function-async get_string_null_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 3 }

drsAlertCurrentStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0004 Current status of object causing the alert."
--DEFAULT get-function-async get_dellstatus_unknow_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 4 }

drsAlertPreviousStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0005 Previous status of object causing the
alert."
--DEFAULT get-function-async get_dellstatus_unknow_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 5 }

drsAlertData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1024))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0006 Alert data."
--DEFAULT get-function-async get_string_null_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 6 }

alertDrscTestTrapEvent TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC generated a test trap event in response to a user
request."
--#TYPE "Dell RAC Test TRAP Event"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Status Events
::= 1001

alertDrscAuthError TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Authentication Failures during a time period have
Exceeded a Threshold."
--#TYPE "Dell RAC Authentication Error"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1002

alertDrscLostESM TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC cannot communicate with the baseboard management
controller (ESM)."
--#TYPE "Dell RAC Lost Communication with ESM"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1003

alertDrscFoundESM TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC is communicating normally with the baseboard management
controller (ESM)."
--#TYPE "Dell RAC Communication with ESM is OK"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1004

alertDrscPowerOff TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a System power state change to
powered-off."
--#TYPE "Dell RAC Detected System Powered-Off"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1005

alertDrscPowerOn TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a system power state change to
powered-on."
--#TYPE "Dell RAC Detected System Powered-On"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1006

alertDrscWatchdogExpired TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the system watchdog has expired
indicating a system hang."
--#TYPE "Dell RAC Detected Watchdog Expired"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1007

alertDrscBattLow TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Battery charge is below 25% indicating that the battery
may only be able to power the DRSC for 8-10 minutes."
--#TYPE "Dell RAC Battery Charge Low"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1008

alertDrscTempNormal TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Temperature probe has retured to a normal value."
--#TYPE "Dell RAC Temperature Normal"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1009

alertDrscTempWarning TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Temperature probe has detected a Warning value."
--#TYPE "Dell RAC Temperature Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1010

alertDrscTempCritical TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Temperature probe has detected a failure (or critical)
value."
--#TYPE "Dell RAC Temperature Failure"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1011

alertDrscVoltNormal TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC voltage has returned to a normal value."
--#TYPE "Dell RAC Voltage Normal"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1012

alertDrscVoltWarning TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC voltage probe has detected a warning value."
--#TYPE "Dell RAC Battery Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1013

alertDrscVoltCritical TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC voltage probe has detected a failure (or critical)
value."
--#TYPE "Dell RAC Voltage Failure"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1014

alertDrscSELWarning TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a new event in the System Event Log with
Severity: Warning."
--#TYPE "Dell RAC System Event Log Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Error Events
::= 1015

alertDrscSELCritical TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a new event in the System Event Log with
Severity: Critical."
--#TYPE "Dell RAC System Event Log Critical"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1016

alertDrscSEL80percentFull TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the System Event Log is 80% full."
--#TYPE "Dell System Event Log 80% Full Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Status Events
::= 1017

alertDrscSEL90percentFull TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the System Event Log is 90% full."
--#TYPE " Dell System Event Log 90% Full Warning "
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Status Events
::= 1018

alertDrscSEL100percentFull TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the System Event Log is 100% full."
--#TYPE " Dell System Event Log 100% Full Warning "
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Status Events
::= 1019

alertDrscSELNormal TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a new event in the System Event Log with
Severity: Normal."
--#TYPE "Dell RAC System Event Log Normal"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1020
END

-------------- next part --------------
A non-text attachment was scrubbed...
Name: walk-x2.log
Type: application/octet-stream
Size: 128233 bytes
Desc: walk-x2.log


[Tim_T_Murphy@localhost net-snmp]$ grep -e "^snmp_agent: tp->start "
agent-logs/1.log

snmp_agent: tp->start SNMPv2-MIB::snmp.33, tp->end
DELL-RAC-MIB::drsProductName,
snmp_agent: tp->start DELL-RAC-MIB::drsProductName, tp->end
DELL-RAC-MIB::drsProductShortName,
snmp_agent: tp->start DELL-RAC-MIB::drsProductName, tp->end
DELL-RAC-MIB::drsProductShortName,
snmp_agent: tp->start DELL-RAC-MIB::drsProductShortName, tp->end
DELL-RAC-MIB::drsProductDescription,
snmp_agent: tp->start DELL-RAC-MIB::drsProductShortName, tp->end
DELL-RAC-MIB::drsProductDescription,
snmp_agent: tp->start DELL-RAC-MIB::drsProductDescription, tp->end
DELL-RAC-MIB::drsProductManufacturer,
snmp_agent: tp->start DELL-RAC-MIB::drsProductDescription, tp->end
DELL-RAC-MIB::drsProductManufacturer,
snmp_agent: tp->start DELL-RAC-MIB::drsProductManufacturer, tp->end
DELL-RAC-MIB::drsProductVersion,
snmp_agent: tp->start DELL-RAC-MIB::drsProductManufacturer, tp->end
DELL-RAC-MIB::drsProductVersion,
snmp_agent: tp->start DELL-RAC-MIB::drsProductVersion, tp->end
DELL-RAC-MIB::drsChassisServiceTag,
snmp_agent: tp->start DELL-RAC-MIB::drsProductVersion, tp->end
DELL-RAC-MIB::drsChassisServiceTag,
snmp_agent: tp->start DELL-RAC-MIB::drsChassisServiceTag, tp->end
DELL-RAC-MIB::drsProductURL,
snmp_agent: tp->start DELL-RAC-MIB::drsChassisServiceTag, tp->end
DELL-RAC-MIB::drsProductURL,
snmp_agent: tp->start DELL-RAC-MIB::drsProductURL, tp->end
DELL-RAC-MIB::drsProductChassisAssetTag,
snmp_agent: tp->start DELL-RAC-MIB::drsProductURL, tp->end
DELL-RAC-MIB::drsProductChassisAssetTag,
snmp_agent: tp->start DELL-RAC-MIB::drsProductChassisAssetTag, tp->end
DELL-RAC-MIB::drsProductChassisLocation,
snmp_agent: tp->start DELL-RAC-MIB::drsProductChassisAssetTag, tp->end
DELL-RAC-MIB::drsProductChassisLocation,
snmp_agent: tp->start DELL-RAC-MIB::drsProductChassisLocation, tp->end
DELL-RAC-MIB::drsProductChassisName,
snmp_agent: tp->start DELL-RAC-MIB::drsProductChassisLocation, tp->end
DELL-RAC-MIB::drsProductChassisName,
snmp_agent: tp->start DELL-RAC-MIB::drsProductChassisName, tp->end
DELL-RAC-MIB::drsSystemServiceTag,
snmp_agent: tp->start DELL-RAC-MIB::drsProductChassisName, tp->end
DELL-RAC-MIB::drsSystemServiceTag,
snmp_agent: tp->start DELL-RAC-MIB::drsSystemServiceTag, tp->end
DELL-RAC-MIB::drsProductSystemAssetTag,
snmp_agent: tp->start DELL-RAC-MIB::drsSystemServiceTag, tp->end
DELL-RAC-MIB::drsProductSystemAssetTag,
snmp_agent: tp->start DELL-RAC-MIB::drsProductSystemAssetTag, tp->end
DELL-RAC-MIB::drsProductSystemSlot,
snmp_agent: tp->start DELL-RAC-MIB::drsProductSystemAssetTag, tp->end
DELL-RAC-MIB::drsProductSystemSlot,
snmp_agent: tp->start DELL-RAC-MIB::drsProductSystemSlot, tp->end
DELL-RAC-MIB::drsProductType,
snmp_agent: tp->start DELL-RAC-MIB::drsProductSystemSlot, tp->end
DELL-RAC-MIB::drsProductType,
snmp_agent: tp->start DELL-RAC-MIB::drsProductType, tp->end
DELL-RAC-MIB::drsProductInfoGroup.15,
snmp_agent: tp->start DELL-RAC-MIB::drsProductType, tp->end
DELL-RAC-MIB::drsProductInfoGroup.15,
snmp_agent: tp->start DELL-RAC-MIB::drsProductInfoGroup.15, tp->end
DELL-RAC-MIB::drsFirmwareVersion,
snmp_agent: tp->start DELL-RAC-MIB::drsFirmwareVersion, tp->end
DELL-RAC-MIB::drsFirmwareGroup.2,
snmp_agent: tp->start DELL-RAC-MIB::drsFirmwareVersion, tp->end
DELL-RAC-MIB::drsFirmwareGroup.2,
snmp_agent: tp->start DELL-RAC-MIB::drsFirmwareGroup.2, tp->end
DELL-RAC-MIB::drsGlobalSystemStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsGlobalSystemStatus, tp->end
DELL-RAC-MIB::drsStatusGroup.2,
snmp_agent: tp->start DELL-RAC-MIB::drsGlobalSystemStatus, tp->end
DELL-RAC-MIB::drsStatusGroup.2,
snmp_agent: tp->start DELL-RAC-MIB::drsStatusGroup.2, tp->end
DELL-RAC-MIB::drsGlobalCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsGlobalCurrStatus, tp->end
DELL-RAC-MIB::drsIOMCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsGlobalCurrStatus, tp->end
DELL-RAC-MIB::drsIOMCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsIOMCurrStatus, tp->end
DELL-RAC-MIB::drsKVMCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsIOMCurrStatus, tp->end
DELL-RAC-MIB::drsKVMCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsKVMCurrStatus, tp->end
DELL-RAC-MIB::drsRedCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsKVMCurrStatus, tp->end
DELL-RAC-MIB::drsRedCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsRedCurrStatus, tp->end
DELL-RAC-MIB::drsPowerCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsRedCurrStatus, tp->end
DELL-RAC-MIB::drsPowerCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsPowerCurrStatus, tp->end
DELL-RAC-MIB::drsFanCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsPowerCurrStatus, tp->end
DELL-RAC-MIB::drsFanCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsFanCurrStatus, tp->end
DELL-RAC-MIB::drsBladeCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsFanCurrStatus, tp->end
DELL-RAC-MIB::drsBladeCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsBladeCurrStatus, tp->end
DELL-RAC-MIB::drsTempCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsBladeCurrStatus, tp->end
DELL-RAC-MIB::drsTempCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsTempCurrStatus, tp->end
DELL-RAC-MIB::drsCMCCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsTempCurrStatus, tp->end
DELL-RAC-MIB::drsCMCCurrStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCCurrStatus, tp->end
DELL-RAC-MIB::drsStatusNowGroup.10,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCCurrStatus, tp->end
DELL-RAC-MIB::drsStatusNowGroup.10,
snmp_agent: tp->start DELL-RAC-MIB::drsStatusNowGroup.10, tp->end
DELL-RAC-MIB::drsGlobalPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsGlobalPrevStatus, tp->end
DELL-RAC-MIB::drsIOMPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsGlobalPrevStatus, tp->end
DELL-RAC-MIB::drsIOMPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsIOMPrevStatus, tp->end
DELL-RAC-MIB::drsKVMPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsIOMPrevStatus, tp->end
DELL-RAC-MIB::drsKVMPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsKVMPrevStatus, tp->end
DELL-RAC-MIB::drsRedPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsKVMPrevStatus, tp->end
DELL-RAC-MIB::drsRedPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsRedPrevStatus, tp->end
DELL-RAC-MIB::drsPowerPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsRedPrevStatus, tp->end
DELL-RAC-MIB::drsPowerPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsPowerPrevStatus, tp->end
DELL-RAC-MIB::drsFanPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsPowerPrevStatus, tp->end
DELL-RAC-MIB::drsFanPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsFanPrevStatus, tp->end
DELL-RAC-MIB::drsBladePrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsFanPrevStatus, tp->end
DELL-RAC-MIB::drsBladePrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsBladePrevStatus, tp->end
DELL-RAC-MIB::drsTempPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsBladePrevStatus, tp->end
DELL-RAC-MIB::drsTempPrevStatus,
snmp_agent: tp->start DELL-RAC-MIB::drsTempPrevStatus, tp->end
DELL-RAC-MIB::drsGlobalChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsGlobalChangeTime, tp->end
DELL-RAC-MIB::drsIOMChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsGlobalChangeTime, tp->end
DELL-RAC-MIB::drsIOMChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsIOMChangeTime, tp->end
DELL-RAC-MIB::drsKVMChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsIOMChangeTime, tp->end
DELL-RAC-MIB::drsKVMChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsKVMChangeTime, tp->end
DELL-RAC-MIB::drsRedChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsKVMChangeTime, tp->end
DELL-RAC-MIB::drsRedChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsRedChangeTime, tp->end
DELL-RAC-MIB::drsPowerChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsRedChangeTime, tp->end
DELL-RAC-MIB::drsPowerChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsPowerChangeTime, tp->end
DELL-RAC-MIB::drsFanChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsPowerChangeTime, tp->end
DELL-RAC-MIB::drsFanChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsFanChangeTime, tp->end
DELL-RAC-MIB::drsBladeChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsFanChangeTime, tp->end
DELL-RAC-MIB::drsBladeChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsBladeChangeTime, tp->end
DELL-RAC-MIB::drsTempChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsBladeChangeTime, tp->end
DELL-RAC-MIB::drsTempChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsTempChangeTime, tp->end
DELL-RAC-MIB::drsCMCChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsTempChangeTime, tp->end
DELL-RAC-MIB::drsCMCChangeTime,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCChangeTime, tp->end
DELL-RAC-MIB::drsStatusChangeGroup.10,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCChangeTime, tp->end
DELL-RAC-MIB::drsStatusChangeGroup.10,
snmp_agent: tp->start DELL-RAC-MIB::drsStatusChangeGroup.10, tp->end
DELL-RAC-MIB::drsCMCPowerTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
snmp_agent: tp->start DELL-RAC-MIB::drsChassisPowerGroup.3, tp->end
SNMPv2-SMI::snmpModules.10.2.1.1,
snmp_agent: tp->start SNMPv2-SMI::snmpModules.10.2.1.1, tp->end
SNMPv2-SMI::snmpModules.10.2.1.2,

[Tim_T_Murphy@localhost net-snmp]$

# log details below, starting just before table fetch

snmp_agent: tp->start DELL-RAC-MIB::drsCMCChangeTime, tp->end
DELL-RAC-MIB::drsStatusChangeGroup.10,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x10160848 reqinfo 0x1014fd58 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x10160848 reqinfo 0x1014fd58 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler serialize for mode GETNEXT
trace: netsnmp_serialize_helper_handler(): serialize.c, 56:
helper:serialize: Got request
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler scalar for mode GETNEXT
trace: netsnmp_scalar_helper_handler(): scalar.c, 139:
helper:scalar: Got request:
trace: netsnmp_scalar_helper_handler(): scalar.c, 145:
helper:scalar: oidELL-RAC-MIB::drsTempChangeTime.0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler instance for mode GETNEXT
trace: netsnmp_instance_helper_handler(): instance.c, 960:
helper:instance: Got request:
trace: netsnmp_instance_helper_handler(): instance.c, 965:
helper:instance: oidELL-RAC-MIB::drsTempChangeTime.0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler drsCMCChangeTime for mode GET
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler drsCMCChangeTime returned 0
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler instance returned 0
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler scalar returned 0
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler serialize returned 0
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=0
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=0
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_trace:
netsnmp_view_get(): vacm.c, 486:
vacm:getView: , found
, vt=1
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=0 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_handle_request(): snmp_agent.c, 3084:
results: request results (status = 0):
trace: netsnmp_handle_request(): snmp_agent.c, 3087:
results: DELL-RAC-MIB::drsCMCChangeTime.0 = Timeticks: (12876)
0:02:08.76
trace: _snmp_build(): snmp_api.c, 2971:
snmp_send: Building SNMPv2 message...
trace: _snmp_build(): snmp_api.c, 2974:
dumph_send: RESPONSE
trace: snmp_pdu_realloc_rbuild(): snmp_api.c, 3342:
snmp_pdu_realloc_rbuild: starting
trace: snmp_pdu_realloc_rbuild(): snmp_api.c, 3357:
dumph_send: VarBind
trace: snmp_realloc_rbuild_var_op(): snmp.c, 341:
dumph_send: Value
dumpx_send: 43 02 32 4C
dumpv_send: UInteger: 12876 (0x324C)
trace: snmp_realloc_rbuild_var_op(): snmp.c, 442:
dumph_send: Name
dumpx_send: 06 0E 2B 06 01 04 01 85 22 D5 0C 02 03 03 09 00
dumpv_send: ObjID: DELL-RAC-MIB::drsCMCChangeTime.0
trace: snmp_pdu_realloc_rbuild(): snmp_api.c, 3425:
dumph_send: error index
dumpx_send: 02 01 00
dumpv_send: Integer: 0 (0x00)
trace: snmp_pdu_realloc_rbuild(): snmp_api.c, 3438:
dumph_send: error status
dumpx_send: 02 01 00
dumpv_send: Integer: 0 (0x00)
trace: snmp_pdu_realloc_rbuild(): snmp_api.c, 3451:
dumph_send: request_id
dumpx_send: 02 04 42 8C 0D 2B
dumpv_send: Integer: 1116474667 (0x428C0D2B)
trace: _snmp_build(): snmp_api.c, 2980:
dumph_send: Community String
dumpx_send: 04 06 70 75 62 6C 69 63
dumpv_send: String: public
trace: _snmp_build(): snmp_api.c, 2996:
dumph_send: SNMP Version Number
dumpx_send: 02 01 01
dumpv_send: Integer: 1 (0x01)
trace: _snmp_build(): snmp_api.c, 3018:
dumph_send: SNMPv2c Message
trace: netsnmp_udp_send(): snmpUDPDomain.c, 263:
netsnmp_udp: send 51 bytes from 0x10181765 to UDP: [192.168.0.120]:1042
on fd 4
trace: netsnmp_remove_and_free_agent_snmp_session(): snmp_agent.c, 1707:
snmp_agent: REMOVE session == 0x10160848
trace: free_agent_snmp_session(): snmp_agent.c, 1299:
snmp_agent: agent_session 0x10160848 released
trace: free_agent_snmp_session(): snmp_agent.c, 1304:
verbose:asp: asp 0x10160848 reqinfo 0x1014fd58 freed
trace: handle_snmp_packet(): snmp_agent.c, 1856:
snmp_agent: end of handle_snmp_packet, asp = 0x10160848
trace: snmp_sess_select_info(): snmp_api.c, 5875:
sess_select: for all sessions: 4
sess_select: next alarm 1.264693400 sec
sess_select: blocking:no session requests or alarms.
trace: receive(): snmpd.c, 1136:
snmpd/select: select( numfds=5, ..., tvp=(nil))
trace: receive(): snmpd.c, 1140:
snmpd/select: returned, count = 1
trace: netsnmp_udp_recvfrom(): snmpUDPDomain.c, 144:
netsnmp_udp: got source addr: 192.168.0.120
trace: netsnmp_udp_recvfrom(): snmpUDPDomain.c, 149:
netsnmp_udp: got destination (local) addr 192.168.0.120
trace: netsnmp_udp_recv(): snmpUDPDomain.c, 227:
netsnmp_udp: recvfrom fd 4 got 49 bytes (from UDP: [192.168.0.120]:1042)
trace: _sess_process_packet(): snmp_api.c, 5125:
sess_process_packet: session 0x1015df98 fd 4 pkt 0x101708a0 length 49
Received SNMP packet(s) from UDP: [192.168.0.120]:1042
dumpx_recv:02 01 01
dumpv_recv: Integer: 1 (0x01)
trace: _snmp_parse(): snmp_api.c, 4127:
snmp_api: Parsing SNMPv2 message...
trace: _snmp_parse(): snmp_api.c, 4137:
dumph_recv: SNMPv2c message

trace: snmp_comstr_parse(): snmp_auth.c, 135:
dumph_recv: SNMP version
dumpx_recv: 02 01 01
dumpv_recv: Integer: 1 (0x01)
trace: snmp_comstr_parse(): snmp_auth.c, 147:
dumph_recv: community string
dumpx_recv: 04 06 70 75 62 6C 69 63
dumpv_recv: String: public
trace: _snmp_parse(): snmp_api.c, 4183:
dumph_recv: PDU
trace: snmp_pdu_parse(): snmp_api.c, 4289:
dumpv_recv: Command GETNEXT
trace: snmp_pdu_parse(): snmp_api.c, 4370:
dumph_recv: request_id
dumpx_recv: 02 04 42 8C 0D 2C
dumpv_recv: Integer: 1116474668 (0x428C0D2C)
trace: snmp_pdu_parse(): snmp_api.c, 4381:
dumph_recv: error status
dumpx_recv: 02 01 00
dumpv_recv: Integer: 0 (0x00)
trace: snmp_pdu_parse(): snmp_api.c, 4392:
dumph_recv: error index
dumpx_recv: 02 01 00
dumpv_recv: Integer: 0 (0x00)
trace: snmp_pdu_parse(): snmp_api.c, 4410:
dumph_recv: VarBindList
trace: snmp_pdu_parse(): snmp_api.c, 4440:
dumph_recv: VarBind
trace: snmp_parse_var_op(): snmp.c, 166:
dumph_recv: Name
dumpx_recv: 06 0E 2B 06 01 04 01 85 22 D5 0C 02 03 03 09 00
dumpv_recv: ObjID: DELL-RAC-MIB::drsCMCChangeTime.0
trace: snmp_pdu_parse(): snmp_api.c, 4449:
dumph_recv: Value
GETNEXT message
-- DELL-RAC-MIB::drsCMCChangeTime.0
trace: init_agent_snmp_session(): snmp_agent.c, 1273:
snmp_agent: agent_sesion 0x1015b9a0 created
trace: init_agent_snmp_session(): snmp_agent.c, 1288:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 created
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=5
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=5
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, Done checking
setup
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=5 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_subtree_find_prev(): agent_registry.c, 1492:
wtest: oid in: DELL-RAC-MIB::drsCMCChangeTime.0
trace: netsnmp_subtree_find_prev(): agent_registry.c, 1503:
wtest: oid cmp: DELL-RAC-MIB::drsCMCChangeTime --- off = 12, in off = 0
test = 1
trace: netsnmp_subtree_find_prev(): agent_registry.c, 1503:
wtest: oid cmp: DELL-RAC-MIB::drsStatusChangeGroup.10 --- off = 12, in
off = 13 test = 1
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsCMCChangeTime.0, 0x1012a910)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCChangeTime, tp->end
DELL-RAC-MIB::drsStatusChangeGroup.10,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler serialize for mode GETNEXT
trace: netsnmp_serialize_helper_handler(): serialize.c, 56:
helper:serialize: Got request
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler scalar for mode GETNEXT
trace: netsnmp_scalar_helper_handler(): scalar.c, 139:
helper:scalar: Got request:
trace: netsnmp_scalar_helper_handler(): scalar.c, 145:
helper:scalar: oidELL-RAC-MIB::drsCMCChangeTime.0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler instance for mode GETNEXT
trace: netsnmp_instance_helper_handler(): instance.c, 960:
helper:instance: Got request:
trace: netsnmp_instance_helper_handler(): instance.c, 965:
helper:instance: oidELL-RAC-MIB::drsCMCChangeTime.0
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler instance returned 0
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler scalar returned 0
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler serialize returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 5
DELL-RAC-MIB::drsCMCChangeTime.0 = Wrong Type (should be Timeticks):
NULL
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsCMCChangeTime.0, 0x1012aa30)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsStatusChangeGroup.10, tp->end
DELL-RAC-MIB::drsCMCPowerTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler null for mode GETNEXT
trace: netsnmp_null_handler(): null.c, 43:
helper:null: Got request
trace: netsnmp_null_handler(): null.c, 45:
helper:null: oidELL-RAC-MIB::drsCMCChangeTime.0
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler null returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 5
DELL-RAC-MIB::drsCMCChangeTime.0 = Wrong Type (should be Timeticks):
NULL
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsCMCChangeTime.0, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsCMCChangeTime.0
trace: table_helper_handler(): table.c, 464:
helper:table: no column/index in request
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsCMCPowerTable
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 1, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsCMCPowerTable
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsPotentialPower = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsPotentialPower, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsPotentialPower
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (2)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete:
DELL-RAC-MIB::drsPotentialPower
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 2, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsPotentialPower
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsIdlePower = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1, DELL-RAC-MIB::drsIdlePower,
0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsIdlePower
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (3)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsIdlePower
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 3, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsIdlePower
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsMaxPowerSpecification = Wrong Type (should be OCTET
STRING): Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsMaxPowerSpecification, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsMaxPowerSpecification
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (4)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete:
DELL-RAC-MIB::drsMaxPowerSpecification
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 4, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup
oidELL-RAC-MIB::drsMaxPowerSpecification
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsPowerSurplus = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsPowerSurplus, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsPowerSurplus
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (5)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsPowerSurplus
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 5, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsPowerSurplus
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsKWhCumulative = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsKWhCumulative, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsKWhCumulative
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (6)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsKWhCumulative
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 6, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsKWhCumulative
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsKWhCumulativeTime = Wrong Type (should be OCTET
STRING): Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsKWhCumulativeTime, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsKWhCumulativeTime
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (7)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete:
DELL-RAC-MIB::drsKWhCumulativeTime
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 7, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsKWhCumulativeTime
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsWattsPeakUsage = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsWattsPeakUsage, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsWattsPeakUsage
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (8)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete:
DELL-RAC-MIB::drsWattsPeakUsage
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 8, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsWattsPeakUsage
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsWattsPeakTime = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsWattsPeakTime, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsWattsPeakTime
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (9)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsWattsPeakTime
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 9, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsWattsPeakTime
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsWattsMinUsage = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsWattsMinUsage, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsWattsMinUsage
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (10)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsWattsMinUsage
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 10, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsWattsMinUsage
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsWattsMinTime = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsWattsMinTime, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsWattsMinTime
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (11)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsWattsMinTime
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 11, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsWattsMinTime
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsWattsResetTime = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsWattsResetTime, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsWattsResetTime
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (12)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete:
DELL-RAC-MIB::drsWattsResetTime
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 12, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsWattsResetTime
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsWattsReading = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsWattsReading, 0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsWattsReading
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (13)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsWattsReading
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 13, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsWattsReading
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsAmpsReading = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1, DELL-RAC-MIB::drsAmpsReading,
0x1012b0b8)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPowerTable, tp->end
DELL-RAC-MIB::drsCMCPSUTable,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPowerTable
DELL-RAC-MIB::drsAmpsReading
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (14)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 1 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsAmpsReading
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 14, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsAmpsReading
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 5
DELL-RAC-MIB::drsAmpsReading = Wrong Type (should be OCTET STRING): NULL
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1, DELL-RAC-MIB::drsAmpsReading,
0x1012bc20)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPSUTable
DELL-RAC-MIB::drsAmpsReading
trace: table_helper_handler(): table.c, 464:
helper:table: no column/index in request
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 2 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsCMCPSUTable
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 1, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0trace: sprint_realloc_by_type():
mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsCMCPSUTable
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsPSUIndex = Wrong Type (should be INTEGER): Variable has
bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1, DELL-RAC-MIB::drsPSUIndex,
0x1012bc20)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPSUTable
DELL-RAC-MIB::drsPSUIndex
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (2)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 2 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsPSUIndex
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 2, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0trace: sprint_realloc_by_type():
mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsPSUIndex
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsPSULocation = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1, DELL-RAC-MIB::drsPSULocation,
0x1012bc20)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPSUTable
DELL-RAC-MIB::drsPSULocation
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (3)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 2 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete: DELL-RAC-MIB::drsPSULocation
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 3, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0trace: sprint_realloc_by_type():
mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsPSULocation
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsPSUMonitoringCapable = Wrong Type (should be INTEGER):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsPSUMonitoringCapable, 0x1012bc20)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPSUTable
DELL-RAC-MIB::drsPSUMonitoringCapable
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (4)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 2 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete:
DELL-RAC-MIB::drsPSUMonitoringCapable
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 4, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0trace: sprint_realloc_by_type():
mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsPSUMonitoringCapable
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsPSUVoltsReading = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsPSUVoltsReading, 0x1012bc20)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPSUTable
DELL-RAC-MIB::drsPSUVoltsReading
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (5)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 2 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete:
DELL-RAC-MIB::drsPSUVoltsReading
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 5, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0trace: sprint_realloc_by_type():
mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsPSUVoltsReading
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsPSUAmpsReading = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsPSUAmpsReading, 0x1012bc20)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPSUTable
DELL-RAC-MIB::drsPSUAmpsReading
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (6)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 2 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete:
DELL-RAC-MIB::drsPSUAmpsReading
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 6, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0trace: sprint_realloc_by_type():
mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsPSUAmpsReading
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 199
trace: sprint_realloc_by_type(): mib.c, 2001:
sprint_by_type: bad type: 199
DELL-RAC-MIB::drsPSUWattsReading = Wrong Type (should be OCTET STRING):
Variable has bad type
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsPSUWattsReading, 0x1012bc20)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsCMCPSUTable, tp->end
DELL-RAC-MIB::drsChassisPowerGroup.3,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table for mode GETNEXT
trace: table_helper_handler(): table.c, 181:
helper:table:req: Got request for handler table: base
oidELL-RAC-MIB::drsCMCPSUTable
DELL-RAC-MIB::drsPSUWattsReading
trace: table_helper_handler(): table.c, 375:
helper:table:col: have at least a column (7)
trace: table_helper_handler(): table.c, 442:
helper:table: not enough for indexes
trace: table_helper_handler(): table.c, 499:
helper:table: looking for 2 indexes
trace: table_helper_handler(): table.c, 508:
helper:table: oid indexes not complete:
DELL-RAC-MIB::drsPSUWattsReading
trace: table_helper_handler(): table.c, 553:
helper:table:results: found 0 indexes
trace: table_helper_handler(): table.c, 561:
helper:table:results: column: 7, indexes: 0trace:
sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0trace: sprint_realloc_by_type():
mib.c, 1941:
output: sprint_by_type, type 2
index: type=2(02), value=INTEGER: 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler table_container for mode GETNEXT
trace: _container_table_handler(): table_container.c, 575:
table_container: Mode GETNEXT, Got request:
trace: _data_lookup(): table_container.c, 464:
table_container: data_lookup oidELL-RAC-MIB::drsPSUWattsReading
trace: _data_lookup(): table_container.c, 515:
table_container: no row found
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table_container returned 0
sparse: retry for NOSUCHOBJECT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler table returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 5
DELL-RAC-MIB::drsPSUWattsReading = Wrong Type (should be OCTET STRING):
NULL
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsPSUWattsReading, 0x1012bd28)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start DELL-RAC-MIB::drsChassisPowerGroup.3, tp->end
SNMPv2-SMI::snmpModules.10.2.1.1,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler null for mode GETNEXT
trace: netsnmp_null_handler(): null.c, 43:
helper:null: Got request
trace: netsnmp_null_handler(): null.c, 45:
helper:null: oidELL-RAC-MIB::drsPSUWattsReading
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler null returned 0
trace: handle_getnext_loop(): snmp_agent.c, 2914:
results: getnext results, before next pass:
trace: handle_getnext_loop(): snmp_agent.c, 2917:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 5
DELL-RAC-MIB::drsPSUWattsReading = Wrong Type (should be OCTET STRING):
NULL
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1868:
snmp_agent: add_vb_to_cache(0x1015b9a0, 1,
DELL-RAC-MIB::drsPSUWattsReading, 0x10139760)
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=12
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=12
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_
trace: netsnmp_view_subtree_check(): vacm.c, 525:
9:vacm:checkSubtree: view _all_
trace: netsnmp_view_subtree_check(): vacm.c, 562:
9:vacm:checkSubtree: _all_ matched?
trace: netsnmp_view_subtree_check(): vacm.c, 623:
9:vacm:checkSubtree: (null) matched
trace: netsnmp_view_subtree_check(): vacm.c, 646:
vacm:checkSubtree: , included
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=12 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1939:
snmp_agent: tp->start SNMPv2-SMI::snmpModules.10.2.1.1, tp->end
SNMPv2-SMI::snmpModules.10.2.1.2,
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1959:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_add_varbind_to_cache(): snmp_agent.c, 1966:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 assigned to request
trace: netsnmp_call_handlers(): agent_handler.c, 510:
handler:calling: main handler bulk_to_next
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler bulk_to_next for mode GETNEXT
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler bulk_to_next returned 0
trace: netsnmp_call_handler(): agent_handler.c, 430:
handler:calling: calling handler old_api for mode GETNEXT
trace: header_generic(): mibgroup/util_funcs.c, 872:
util_funcs: header_generic: DELL-RAC-MIB::drsPSUWattsReading exact=0
trace: header_generic(): mibgroup/util_funcs.c, 880:
util_funcs: result: -1
trace: netsnmp_call_handler(): agent_handler.c, 438:
handler:returned: handler old_api returned 0
trace: _callback_lock(): callback.c, 118:
9:callback:lock: locked (APP,null)
trace: snmp_call_callbacks(): callback.c, 304:
callback: START calling callbacks for maj=1 min=0
trace: snmp_call_callbacks(): callback.c, 318:
callback: calling a callback for maj=1 min=0
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1287:
mibII/vacm_vars: vacm_in_view: ver=1, community=public
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1240:
netsnmp_udp_getSecName: resolve <"public", 0xc0a80078>
trace: netsnmp_udp_getSecName(): snmpUDPDomain.c, 1245:
netsnmp_udp_getSecName: compare <"public", 0x00000000/0x00000000>...
SUCCESS
trace: netsnmp_subtree_find_first(): agent_registry.c, 156:
subtree: looking for subtree for context: ""
trace: netsnmp_subtree_find_first(): agent_registry.c, 160:
subtree: found one for: ""
trace: vacm_check_view(): mibgroup/mibII/vacm_conf.c, 1414:
mibII/vacm_vars: vacm_in_view: sn=comm1, gn=grpcomm1, vn=_all_trace:
netsnmp_view_get(): vacm.c, 486:
vacm:getView: , found
, vt=1
trace: snmp_call_callbacks(): callback.c, 330:
callback: END calling callbacks for maj=1 min=0 (1 called)
trace: _callback_unlock(): callback.c, 150:
9:callback:lock: unlocked (APP,null)
trace: netsnmp_handle_request(): snmp_agent.c, 3084:
results: request results (status = 0):
trace: netsnmp_handle_request(): snmp_agent.c, 3087:
results: trace: sprint_realloc_by_type(): mib.c, 1941:
output: sprint_by_type, type 4
SNMPv2-SMI::snmpModules.10.2.1.1.0 = Hex-STRING: 80 00 1F 88 80 0A 4F 99
74 48 06 4F D2
trace: _snmp_build(): snmp_api.c, 2971:
snmp_send: Building SNMPv2 message...
trace: _snmp_build(): snmp_api.c, 2974:
dumph_send: RESPONSE
trace: snmp_pdu_realloc_rbuild(): snmp_api.c, 3342:
snmp_pdu_realloc_rbuild: starting
trace: snmp_pdu_realloc_rbuild(): snmp_api.c, 3357:
dumph_send: VarBind
trace: snmp_realloc_rbuild_var_op(): snmp.c, 341:
dumph_send: Value
dumpx_send: 04 0D 80 00 1F 88 80 0A 4F 99 74 48 06 4F D2
dumpv_send: String: .....
O.tH.O.
trace: snmp_realloc_rbuild_var_op(): snmp.c, 442:
dumph_send: Name
dumpx_send: 06 0A 2B 06 01 06 03 0A 02 01 01 00
dumpv_send: ObjID: SNMPv2-SMI::snmpModules.10.2.1.1.0
trace: snmp_pdu_realloc_rbuild(): snmp_api.c, 3425:
dumph_send: error index
dumpx_send: 02 01 00
dumpv_send: Integer: 0 (0x00)
trace: snmp_pdu_realloc_rbuild(): snmp_api.c, 3438:
dumph_send: error status
dumpx_send: 02 01 00
dumpv_send: Integer: 0 (0x00)
trace: snmp_pdu_realloc_rbuild(): snmp_api.c, 3451:
dumph_send: request_id
dumpx_send: 02 04 42 8C 0D 2C
dumpv_send: Integer: 1116474668 (0x428C0D2C)
trace: _snmp_build(): snmp_api.c, 2980:
dumph_send: Community String
dumpx_send: 04 06 70 75 62 6C 69 63
dumpv_send: String: public
trace: _snmp_build(): snmp_api.c, 2996:
dumph_send: SNMP Version Number
dumpx_send: 02 01 01
dumpv_send: Integer: 1 (0x01)
trace: _snmp_build(): snmp_api.c, 3018:
dumph_send: SNMPv2c Message
trace: netsnmp_udp_send(): snmpUDPDomain.c, 263:
netsnmp_udp: send 58 bytes from 0x1018175e to UDP: [192.168.0.120]:1042
on fd 4
trace: netsnmp_remove_and_free_agent_snmp_session(): snmp_agent.c, 1707:
snmp_agent: REMOVE session == 0x1015b9a0
trace: free_agent_snmp_session(): snmp_agent.c, 1299:
snmp_agent: agent_session 0x1015b9a0 released
trace: free_agent_snmp_session(): snmp_agent.c, 1304:
verbose:asp: asp 0x1015b9a0 reqinfo 0x1015d128 freed
trace: handle_snmp_packet(): snmp_agent.c, 1856:
snmp_agent: end of handle_snmp_packet, asp = 0x1015b9a0
trace: snmp_sess_select_info(): snmp_api.c, 5875:
sess_select: for all sessions: 4
sess_select: next alarm 1.264693400 sec
sess_select: blocking:no session requests or alarms.
trace: receive(): snmpd.c, 1136:
snmpd/select: select( numfds=5, ..., tvp=(nil))
------------------------------

-------------------------------------------------------------------------
This SF.net email is sponsored by the 2008 JavaOne(SM) Conference
Don't miss this year's exciting event. There's still time to save $100.
Use priority code J8TL2D2.
http://ad.doubleclick.net/clk;198757...un.com/javaone
_______________________________________________
Net-snmp-coders mailing list
Net-snmp-coders@lists.sourceforge.net
https://lists.sourceforge.net/lists/...et-snmp-coders