On 20/07/07, vincenzobonvino@tin.it wrote:
> 2007-07-20 15:34:45 [UDP: [127.0.0.1]: 32822]:
> DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (18) 0:00:00.18
> SNMPv2-MIB::snmpTrapOID.0 = OID: DISMAN-EVENT-MIB::mteTriggerFired
> DISMAN-EVENT-MIB::mteHotTrigger.0 = STRING: warning
> DISMAN-EVENT-MIB::mteHotTargetName.0 = STRING:
> DISMAN-EVENT-MIB::mteHotContextName.0 = STRING:



That entry looks suspiciously as if it has been triggered by the
monitor entry "warning".
So I think it *is* actually working.

However:

> DISMAN-EVENT-MIB::mteHotOID.0 = OID: DISMAN-EVENT-MIB::sysUpTimeInstance
> DISMAN-EVENT-MIB::mteHotValue.0 = Wrong Type (should be INTEGER):
> Timeticks: (18) 0:00:00.18


That seems to imply that you are monitoring the MIB object 'sysUpTime'

What object were you expecting to monitor?
What does walking the DisMan Event MIB tables show?

Dave

PS: Can you please keep the same subject line throughout.
Adding "R:" instead of "Re:" is breaking the continuity of this thread!
Thanks

-------------------------------------------------------------------------