On 3/8/08, Vlad GALU wrote:
> On 3/8/08, Robert Watson wrote:
> > On Fri, 7 Mar 2008, Vlad GALU wrote:
> >
> >
> > > I see an unusual symptom with one of our in-house applications. The main I/O
> > > loop calls kevent(), which in turn returns two events with EV_EOF error set,
> > > always for the same descriptors (they're both socket descriptors). As the
> > > man page is not pretty clear about it and I don't have my UNP copy at hand,
> > > I would like to ask the list whether the error events are supposed to be
> > > one-shot or not.

> >
> >
> > I wonder if it's returning one event for the read socket buffer, and one event
> > for the write socket buffer, since there are really two event sources for each
> > socket? Not that this is desirable behavior, but it might explain it. If you
> > shutdown() only read, do you get back one EOF kevent and one writable kevent?

>
>
> I'll try that and see. The only issue being the low frequency this
> symptom appears at. I'll get back to the list once I have more info.


Haven't gotten to the point of testing shutdown() behavior, but
here's a truss excerpt of the symptom:

-- cut here --
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
kevent(3,0x0,0,{0x7,EVFILT_WRITE,EV_EOF,54,0x832c, 0x800d08080
0x7,EVFILT_READ,EV_EOF,54,0x2a,0x800d08080},1024,0 x0) = 2 (0x2)
-- and here --

So two EOF are returrned for descriptor 7, and errno would be
ECONNRESET. The question is now, why isn't it oneshot?

>
>
> >
> > Robert N M Watson
> > Computer Laboratory
> > University of Cambridge
> >

>
>
>
> --
> Mahnahmahnah!
>



--
Mahnahmahnah!
_______________________________________________
freebsd-hackers@freebsd.org mailing list
http://lists.freebsd.org/mailman/lis...reebsd-hackers
To unsubscribe, send any mail to "freebsd-hackers-unsubscribe@freebsd.org"