manual for CMD CQD-200 - DEC

This is a discussion on manual for CMD CQD-200 - DEC ; Anyone have one? --Toby...

+ Reply to Thread
Results 1 to 6 of 6

Thread: manual for CMD CQD-200

  1. manual for CMD CQD-200

    Anyone have one?
    --Toby


  2. Re: manual for CMD CQD-200

    toby wrote:
    > Anyone have one?
    > --Toby


    I have the CQD-220/223....


  3. Re: manual for CMD CQD-200

    bob.birch@gmail.com wrote:
    > toby wrote:
    > > Anyone have one?
    > > --Toby

    >
    > I have the CQD-220/223....


    I do have manuals for CQD-220/223(A), 240/243, 260/263, and 440/443
    from when CMD had them on their web site, but the card I have is the
    200 & no manual :/

    --Toby


  4. Re: manual for CMD CQD-200

    Hi,

    here's some information about the CMD CQD-200. I found ist time ago
    with www.archive.org.
    Greetings,
    Marc

    mcwood addd gmx dot net

    -------------------------------------------------------------------------------------------------------------
    CMD Technical Support
    Jumper Settings for CQD200/203 Qbus to SCSI Controller
    Jumper and switch settings
    Taken from CMD CQD-200/203 Manual Revision 4.1 January 1993

    Models:
    CQD-200/M Disk Only (P22016A or P22016B in U40)
    CQD-200/T Tape Only (P22017A in U40)
    CQD-200/TM Disk and Tape (P22015A in U40)

    The CQD-203 has the MicroVAX-3 metal mounting bracket, otherwise it
    is identical to the CQD-200.

    CQD200/203 Board Layout

    RS-232 SCSI connector LED Indicator
    *-------------------------------------------------------*
    | | J1 | W20| J2 |DS1/DS2 W1 |
    1 = pin one
    | |1_____| oo 1__________________________| || || o-o |
    | 1_______RN1 1________ RN3 |
    220/330 ohm Terminators
    | SCSI TERMINATORS 1________ RN2 |
    710E221331
    | W2 |

    | o o o o o o o |
    | o o o o o o o |
    | 1 2 3 4 5 6 7 |
    | |
    | |
    | |
    | |
    | |
    | |
    | W3 |
    | o o o o |
    | o o o o |
    | _U24_ 1 2 3 4 |
    | | M | _U29_ _U31_ |
    | | I | 1 | 1 | |
    | | C | |F | |F | |
    | | R | |I | |I | |
    | | O | |R | |R | |
    | W4 | P | |M E| |M O| |
    | o-o 1| R | |W V| |W D| |
    | o-o 2| S | |A E| |A D| |
    Even = F200x2xxx
    | o-o 3| S | |R N| |R | |
    Odd = F200x1xxx
    | o-o 4| O | |E | |E | |
    | o-o 5| R | |[2]| |[1]| |
    | | | |___| |___| |
    | |___| |
    | Even Odd |
    | U40 |
    | | | |
    | | | |
    | | | |
    | | | |
    | | | |
    | --- W6 W7 W8 W9 |
    | CSR PAL o o o-o o o o o o |
    | o |
    | W10 |
    | o |
    | o |
    | o |
    | W11 |
    | o |
    | o |
    | o |
    | _____ |
    |||||||||||||||||||||||| ||||||||||||||||||||||||||||
    |||||||||||||||||||||||| ||||||||||||||||||||||||||||
    |||||||||||||||||||||||| ||||||||||||||||||||||||||||
    ------------------------ ----------------------------

    Pin Assignments
    Physical pin number assignments and functions of the RS-232 port
    for accessing the On-Board Utility. Connector J1 pin assignments are
    listed in the following table when you are facing the 10 pin connector
    from the controller's top edge. NOTE: For CMD's On-Board RS-232
    Utility, only pin 3, 8 and grounds are used.

    ________ ________
    | |
    | 9 7 5 3 1 |
    | 10 8 6 4 2 |
    |_____________________|


    Pin Assignments for Utility Interface

    Pin 1 No connect
    Pin 2 Ground
    Pin 3 TXD, transmit data for RS-232 application
    Pin 4 Ground
    Pin 5 No connect
    Pin 6 No connect
    Pin 7 No connect
    Pin 8 RXD, receive data for RS-232 application
    Pin 9 Ground
    Pin 10 No connect

    NOTE
    You cannot use the CQD-200 when the RS-232 port connector is in
    place. Be sure to remove the connector in J1 before using the board.
    For write protection, contact CMD.
    Host Adapter ID Selections

    W2-5 W2-4 W2-3 Initiator ID
    IN IN IN Host adapter ID = 7, highest priority (F)
    IN IN OUT Host adapter ID = 6
    IN OUT IN Host adapter ID = 5
    IN OUT OUT Host adapter ID = 4
    OUT IN IN Host adapter ID = 3
    OUT IN OUT Host adapter ID = 2
    OUT OUT IN Host adapter ID = 1
    OUT OUT OUT Host adapter ID = 0, lowest priority
    Note that (F) means factory setting.

    CQD-200 Pin Assignments

    W1 IN SCSI terminator power enabled (F)
    W1 OUT SCSI terminator power disabled
    W2-1 IN, W2-2 IN * ANSI Mode Selection (F)
    W2-1 IN, W2-2 OUT * MIX Mode Selection
    W2-1 OUT, W2-2 OUT * CMD Mode Selection
    W2-6 IN Enable tape fast search option
    W2-6 OUT Normal operation (F)
    W2-7 OUT Reserved (F)
    W3 OUT All Reserved (F)
    W4-1 IN Bootstrap address = 773000 (F)
    W4-1 OUT Bootstrap address = 771000
    W6 IN Tape Monitor Utility enabled
    W6 OUT Tape Monitor Utility disabled (F)
    W7 1-2 IN Auto-Boot enabled
    W7 2-3 IN Auto-Boot disabled (F)
    W8 IN 22-Bit addressing (F)
    W8 OUT 18-Bit addressing
    W10 1-2 IN Block mode DMA enabled (F)
    W10 2-3 IN Block mode DMA disabled
    W11 1-2 IN Interrupt level 5
    W11 2-3 IN Interrupt level 4 (F)
    W20 OUT Reserved (Hardware Rev. C and up) (F)
    Note that (F) means factory setting.

    * These two jumpers are ignored by CQD-200/M; SCSI host adapter for
    disk only.

    CSR Address Selection for CQD-200/M

    Address LSI-11 MicroVAX W4-2 W4-3 W4-4 W4-5
    Standard 17772150 20001468 (F) IN IN OUT OUT
    Second 17760334 200000DC IN OUT OUT OUT
    Third 17760354 200000EC OUT IN OUT OUT
    Fourth 17760374 200000FC OUT OUT OUT OUT
    Fifth 17760340 200000E0 IN IN IN OUT
    Sixth 17760344 200000E4 IN OUT IN OUT
    Seventh 17760350 200000E8 OUT IN IN OUT
    Eighth 17760360 200000F0 OUT OUT IN OUT
    Note that (F) means factory setting.

    CQD-200/T CSR Address Selections (Rev C & higher)

    Addr LSI-11 MicroVAX W4-1 W4-2 W4-3 W4-4 W4-5
    1 17774500 20001940 (F) IN OUT OUT IN IN
    2 17760404 20000104 IN OUT OUT IN OUT
    3 17760444 20000124 IN OUT OUT OUT IN
    4 17760504 20000144 IN OUT OUT OUT OUT
    5 17760544 20000164 IN OUT IN IN IN
    6 17760410 20000108 IN OUT IN IN OUT
    7 17760450 20000128 IN OUT IN OUT IN
    8 17760454 2000012C IN OUT IN OUT OUT
    9 17760414 2000010C IN IN OUT IN IN
    10 17760420 20000110 IN IN OUT IN OUT
    11 17760460 20000130 IN IN OUT OUT IN
    12 17760510 20000148 IN IN OUT OUT OUT
    13 17760514 2000014C IN IN IN IN IN
    14 17760520 20000150 IN IN IN IN OUT
    15 17760550 20000168 IN IN IN OUT IN
    16 17760554 2000016C IN IN IN OUT OUT
    17 17760560 20000170 OUT OUT OUT IN IN
    18 17760604 20000184 OUT OUT OUT IN OUT
    19 17760610 20000188 OUT OUT OUT OUT IN
    20 17760614 2000018C OUT OUT OUT OUT OUT
    21 17760620 20000190 OUT OUT IN IN IN
    22 17760644 200001A4 OUT OUT IN IN OUT
    23 17760650 200001A8 OUT OUT IN OUT IN
    24 17760654 200001AC OUT OUT IN OUT OUT
    25 17760660 200001B0 OUT IN OUT IN IN
    26 17760704 200001C4 OUT IN OUT IN OUT
    27 17760710 200001C8 OUT IN OUT OUT IN
    28 17760714 200001CC OUT IN OUT OUT OUT
    29 17760744 200001E4 OUT IN IN IN IN
    30 17760750 200001E8 OUT IN IN IN OUT
    Note that (F) means factory setting.

    CQD-200/TM CSR jumper settings for disk

    Addr LSI-11 MicroVAX W4-2 W4-3
    Standard 17772150 20001468 (F) IN IN
    Second 17760334 200000DC IN OUT
    Third 17760354 200000EC OUT IN
    Disable disk OUT OUT
    Note that (F) means factory setting.

    CQD-200/TM CSR jumper settings for tape

    Addr LSI-11 MicroVAX W4-4 W4-5
    Standard 17774500 20001940 (F) IN IN
    Second 17760404 20000104 IN OUT
    Third 17760444 20000124 OUT IN
    Disable tape OUT OUT
    Note that (F) means factory setting.

    The above information can be changed without notice.
    Rev. Date: A = 04-15-96


  5. Re: manual for CMD CQD-200


    mac wrote:
    > Hi,
    >
    > here's some information about the CMD CQD-200. I found ist time ago
    > with www.archive.org.


    Thankyou very much! That's the first bit of information that has turned
    up.
    ---T

    > Greetings,
    > Marc
    >
    > mcwood addd gmx dot net
    >
    > -------------------------------------------------------------------------------------------------------------
    > CMD Technical Support
    > Jumper Settings for CQD200/203 Qbus to SCSI Controller
    > Jumper and switch settings
    > Taken from CMD CQD-200/203 Manual Revision 4.1 January 1993
    >
    > Models:
    > CQD-200/M Disk Only (P22016A or P22016B in U40)
    > CQD-200/T Tape Only (P22017A in U40)
    > CQD-200/TM Disk and Tape (P22015A in U40)
    >
    > The CQD-203 has the MicroVAX-3 metal mounting bracket, otherwise it
    > is identical to the CQD-200.
    >
    > CQD200/203 Board Layout
    >
    > RS-232 SCSI connector LED Indicator
    > *-------------------------------------------------------*
    > | | J1 | W20| J2 |DS1/DS2 W1 |
    > 1 = pin one
    > | |1_____| oo 1__________________________| || || o-o |
    > | 1_______RN1 1________ RN3 |
    > 220/330 ohm Terminators
    > | SCSI TERMINATORS 1________ RN2 |
    > 710E221331
    > | W2 |
    >
    > | o o o o o o o |
    > | o o o o o o o |
    > | 1 2 3 4 5 6 7 |
    > | |
    > | |
    > | |
    > | |
    > | |
    > | |
    > | W3 |
    > | o o o o |
    > | o o o o |
    > | _U24_ 1 2 3 4 |
    > | | M | _U29_ _U31_ |
    > | | I | 1 | 1 | |
    > | | C | |F | |F | |
    > | | R | |I | |I | |
    > | | O | |R | |R | |
    > | W4 | P | |M E| |M O| |
    > | o-o 1| R | |W V| |W D| |
    > | o-o 2| S | |A E| |A D| |
    > Even = F200x2xxx
    > | o-o 3| S | |R N| |R | |
    > Odd = F200x1xxx
    > | o-o 4| O | |E | |E | |
    > | o-o 5| R | |[2]| |[1]| |
    > | | | |___| |___| |
    > | |___| |
    > | Even Odd |
    > | U40 |
    > | | | |
    > | | | |
    > | | | |
    > | | | |
    > | | | |
    > | --- W6 W7 W8 W9 |
    > | CSR PAL o o o-o o o o o o |
    > | o |
    > | W10 |
    > | o |
    > | o |
    > | o |
    > | W11 |
    > | o |
    > | o |
    > | o |
    > | _____ |
    > |||||||||||||||||||||||| ||||||||||||||||||||||||||||
    > |||||||||||||||||||||||| ||||||||||||||||||||||||||||
    > |||||||||||||||||||||||| ||||||||||||||||||||||||||||
    > ------------------------ ----------------------------
    >
    > Pin Assignments
    > Physical pin number assignments and functions of the RS-232 port
    > for accessing the On-Board Utility. Connector J1 pin assignments are
    > listed in the following table when you are facing the 10 pin connector
    > from the controller's top edge. NOTE: For CMD's On-Board RS-232
    > Utility, only pin 3, 8 and grounds are used.
    >
    > ________ ________
    > | |
    > | 9 7 5 3 1 |
    > | 10 8 6 4 2 |
    > |_____________________|
    >
    >
    > Pin Assignments for Utility Interface
    >
    > Pin 1 No connect
    > Pin 2 Ground
    > Pin 3 TXD, transmit data for RS-232 application
    > Pin 4 Ground
    > Pin 5 No connect
    > Pin 6 No connect
    > Pin 7 No connect
    > Pin 8 RXD, receive data for RS-232 application
    > Pin 9 Ground
    > Pin 10 No connect
    >
    > NOTE
    > You cannot use the CQD-200 when the RS-232 port connector is in
    > place. Be sure to remove the connector in J1 before using the board.
    > For write protection, contact CMD.
    > Host Adapter ID Selections
    >
    > W2-5 W2-4 W2-3 Initiator ID
    > IN IN IN Host adapter ID = 7, highest priority (F)
    > IN IN OUT Host adapter ID = 6
    > IN OUT IN Host adapter ID = 5
    > IN OUT OUT Host adapter ID = 4
    > OUT IN IN Host adapter ID = 3
    > OUT IN OUT Host adapter ID = 2
    > OUT OUT IN Host adapter ID = 1
    > OUT OUT OUT Host adapter ID = 0, lowest priority
    > Note that (F) means factory setting.
    >
    > CQD-200 Pin Assignments
    >
    > W1 IN SCSI terminator power enabled (F)
    > W1 OUT SCSI terminator power disabled
    > W2-1 IN, W2-2 IN * ANSI Mode Selection (F)
    > W2-1 IN, W2-2 OUT * MIX Mode Selection
    > W2-1 OUT, W2-2 OUT * CMD Mode Selection
    > W2-6 IN Enable tape fast search option
    > W2-6 OUT Normal operation (F)
    > W2-7 OUT Reserved (F)
    > W3 OUT All Reserved (F)
    > W4-1 IN Bootstrap address = 773000 (F)
    > W4-1 OUT Bootstrap address = 771000
    > W6 IN Tape Monitor Utility enabled
    > W6 OUT Tape Monitor Utility disabled (F)
    > W7 1-2 IN Auto-Boot enabled
    > W7 2-3 IN Auto-Boot disabled (F)
    > W8 IN 22-Bit addressing (F)
    > W8 OUT 18-Bit addressing
    > W10 1-2 IN Block mode DMA enabled (F)
    > W10 2-3 IN Block mode DMA disabled
    > W11 1-2 IN Interrupt level 5
    > W11 2-3 IN Interrupt level 4 (F)
    > W20 OUT Reserved (Hardware Rev. C and up) (F)
    > Note that (F) means factory setting.
    >
    > * These two jumpers are ignored by CQD-200/M; SCSI host adapter for
    > disk only.
    >
    > CSR Address Selection for CQD-200/M
    >
    > Address LSI-11 MicroVAX W4-2 W4-3 W4-4 W4-5
    > Standard 17772150 20001468 (F) IN IN OUT OUT
    > Second 17760334 200000DC IN OUT OUT OUT
    > Third 17760354 200000EC OUT IN OUT OUT
    > Fourth 17760374 200000FC OUT OUT OUT OUT
    > Fifth 17760340 200000E0 IN IN IN OUT
    > Sixth 17760344 200000E4 IN OUT IN OUT
    > Seventh 17760350 200000E8 OUT IN IN OUT
    > Eighth 17760360 200000F0 OUT OUT IN OUT
    > Note that (F) means factory setting.
    >
    > CQD-200/T CSR Address Selections (Rev C & higher)
    >
    > Addr LSI-11 MicroVAX W4-1 W4-2 W4-3 W4-4 W4-5
    > 1 17774500 20001940 (F) IN OUT OUT IN IN
    > 2 17760404 20000104 IN OUT OUT IN OUT
    > 3 17760444 20000124 IN OUT OUT OUT IN
    > 4 17760504 20000144 IN OUT OUT OUT OUT
    > 5 17760544 20000164 IN OUT IN IN IN
    > 6 17760410 20000108 IN OUT IN IN OUT
    > 7 17760450 20000128 IN OUT IN OUT IN
    > 8 17760454 2000012C IN OUT IN OUT OUT
    > 9 17760414 2000010C IN IN OUT IN IN
    > 10 17760420 20000110 IN IN OUT IN OUT
    > 11 17760460 20000130 IN IN OUT OUT IN
    > 12 17760510 20000148 IN IN OUT OUT OUT
    > 13 17760514 2000014C IN IN IN IN IN
    > 14 17760520 20000150 IN IN IN IN OUT
    > 15 17760550 20000168 IN IN IN OUT IN
    > 16 17760554 2000016C IN IN IN OUT OUT
    > 17 17760560 20000170 OUT OUT OUT IN IN
    > 18 17760604 20000184 OUT OUT OUT IN OUT
    > 19 17760610 20000188 OUT OUT OUT OUT IN
    > 20 17760614 2000018C OUT OUT OUT OUT OUT
    > 21 17760620 20000190 OUT OUT IN IN IN
    > 22 17760644 200001A4 OUT OUT IN IN OUT
    > 23 17760650 200001A8 OUT OUT IN OUT IN
    > 24 17760654 200001AC OUT OUT IN OUT OUT
    > 25 17760660 200001B0 OUT IN OUT IN IN
    > 26 17760704 200001C4 OUT IN OUT IN OUT
    > 27 17760710 200001C8 OUT IN OUT OUT IN
    > 28 17760714 200001CC OUT IN OUT OUT OUT
    > 29 17760744 200001E4 OUT IN IN IN IN
    > 30 17760750 200001E8 OUT IN IN IN OUT
    > Note that (F) means factory setting.
    >
    > CQD-200/TM CSR jumper settings for disk
    >
    > Addr LSI-11 MicroVAX W4-2 W4-3
    > Standard 17772150 20001468 (F) IN IN
    > Second 17760334 200000DC IN OUT
    > Third 17760354 200000EC OUT IN
    > Disable disk OUT OUT
    > Note that (F) means factory setting.
    >
    > CQD-200/TM CSR jumper settings for tape
    >
    > Addr LSI-11 MicroVAX W4-4 W4-5
    > Standard 17774500 20001940 (F) IN IN
    > Second 17760404 20000104 IN OUT
    > Third 17760444 20000124 OUT IN
    > Disable tape OUT OUT
    > Note that (F) means factory setting.
    >
    > The above information can be changed without notice.
    > Rev. Date: A = 04-15-96



  6. Re: manual for CMD CQD-200

    toby wrote:
    > mac wrote:
    >> Hi,
    >>
    >> here's some information about the CMD CQD-200. I found ist time ago
    >> with www.archive.org.

    >
    > Thankyou very much! That's the first bit of information that has turned
    > up.


    Thanks for the very timely post - I've been looking for a (cheap...)
    SCSI QBUS card for a while and have been offered a CQD-200 (without
    manual) and have been looking for information on it with no sucess.
    Could anyone outline the differences between a CQD-200 and a CQD-220
    (which is much better documented on the web...)?

    Thanks

    Julian

+ Reply to Thread